Page 12 - 033
P. 12
VESSEL IMPACT ANALYSIS FOR RISER PROTECTION FRAME AND 11
PROTECTION NET SUPPORTS ON SEMI-SUBMERSIBLE OFFSHORE STRUCTURES
different load cases on RPF-01 and RPF-02 supports at different points of collision. Figure 25
~ 36 show different load cases on PN-01 and PN-02 supports at different points of collision.
Figure 14. Load Case–01 for RPF-01 Structure Figure 15. Load Case–02 for RPF-01 Structure
(RPF-01_LC01) (RPF-01_LC02)
Figure 16. Load Case–03 for RPF-01 Structure Figure 17. Load Case–04 for RPF-01 Structure
(RPF-01_LC03) (RPF-01_LC04)
Figure 18. Load Case–05 for RPF-01 Structure Figure 19. Load Case–06 for RPF-01 Structure
(RPF-01_LC05) (RPF-01_LC06)
Sayı 3, 2015 GiDB|DERGi