FAULT TOLERANT CONTROL OF ROTOR SWING 43
                                    STABILIZER SYSTEM USING FMEA METHOD

    Failure mode       Effect                         S                           Cause                                 O RPN

                                                         Drive mode does not be activated

                                                         Park mode does not be activated

                                                         Drive motor does not be activated

                                                         Swivel motor does not be activated

8   Stabilizer is not  The users might complain it        Battery does not transfer the power to power unit             3  21
    folding into       and try to fix it                  User interface does not inform the master control unit to
    streamline on
    park mode /                                           work
    opening on drive                                  7 Master control unit does not inform the battery to work
    mode
                                                          Battery does not transfer the power to master control unit
                                                          Master control unit does not inform the sensors to work
                                                          İnclination angles do not be sensed

                                                         Sensors do not inform the master control unit about

                                                         inclination angle

                                                         Sensors do not inform correctly the master control unit

                                                         about inclination angle

                                                         It takes too much time to open/close the system manually

                                                         Power transfer is interrupted from battery to master control

9   Stabilizer cannot  The users might complain it        unit                                                          3 21
    open/close         and try to fix it              7 Power transfer is interrupted from battery to power unit
    totally
                                                          Drive motor does not be activated

                                                         Drive mode does not be activated

                                                         Park mode does not be activated

    It takes long                                         It takes too much time to open/close the system manually
                                                          Power transfer is interrupted from battery to master control
10  time to            The users might accept or          unit                                                          5  25
    open/close         tolerate it                    5 Power transfer is interrupted from battery to power unit
                                                          Drive motor does not be activated
    stabilizers                                           Drive mode does not be activated
                                                          Park mode does not be activated

                                                          System does not be opened/closed manually
                                                          Rotors do not rotate
                                                          Rotation direction of rotors is not correct
                                                          Rotation direction of rotors is same
                                                          İnclination angles do not be sensed

       User cannot     The users will give up to use      Flow direction and velocity does not be sensed                4 28
11 open/close          the system                         Sensors do not inform the master control unit about
                                                          inclination angle
       stabilizer                                     7 Master control unit does not inform the battery to work
                                                          User interface does not inform the master control unit to
                                                          work
                                                          Battery does not transfer the power to power unit
                                                          Drive motor does not be activated
                                                          Swivel motor does not be activated
                                                          Rotors do not be opened
                                                          Drive mode does not be activated
                                                          Wire damages

    User meet

    difficulties to

12  open/close         The users might complain it    6  Power transfer is interrupted from battery to power unit       3 18
    stabilizer         and try to fix it                 Drive motor does not be activated

    (stabilizer is

    stuck)

    User meet

13  difficulties to    The users might complain it    6  User interface does not inform the master control unit to      5 30
    send correct       and try to fix it                 work

    command

                       Appendix B: Applied FMEA procedure on functions